1、 The switch is on, but the device does not start:
1. Electrical circuit failure, such as broken fuse and wire falling off
2. The thermal protection element is not reset after protection
resolvent:
1. The waterway is under voltage, check the fuse and check the wiring everywhere
2. Reset the thermal protection element
3. Check the waterway and ensure the water supply pressure
2、 After the equipment is started, the water inlet solenoid valve is not opened:
1. The wiring falls off
永旺彩票2. Internal mechanical failure of solenoid valve
3. Solenoid valve coil is broken
resolvent:
1. Check the circuit
2. Disassemble solenoid valve for maintenance
3. Repair or replace the coil
3、 The pump operates but fails to reach the rated pressure and flow:
永旺彩票1. Pump reverse
永旺彩票2. The filter element of the security filter is dirty
永旺彩票3. There is air in the pump
永旺彩票4. Open the flushing solenoid valve
Solution:
1. Rewire
永旺彩票2. Clean or replace the filter element
3. Remove the air in the pump
永旺彩票4. adjust the pressure after flushing
永旺彩票4、 When the system pressure increases, the pump noise is loud
1. Insufficient raw water flow
2. Unstable raw water flow
Solution:
1. Check the raw water pump and pipeline
永旺彩票2. Check the raw water pump and pipeline and check whether there is leakage in the pipeline
5、 The solenoid valve is not closed after flushing
1. Solenoid valve control element and circuit failure
2. Mechanical failure of solenoid valve
resolvent:
1. Check or replace components and circuits
2. Disassemble, repair or replace the solenoid valve
Vi. undervoltage shutdown
1. Insufficient raw water supply
2. The filter element of the security filter is blocked
3. Under pressure caused by improper pressure adjustment and automatic flushing
resolvent:
永旺彩票1. Check whether the raw water pump and pretreatment system are working
永旺彩票2. Clean and replace the filter element 3 Adjust the system pressure to the best state and maintain the filtered pressure above 20psi
永旺彩票7、 The concentrated water pressure cannot reach the rated value
永旺彩票1. Pipeline leakage
2. Flushing solenoid valves are not fully closed
3. Leakage of recovery system
resolvent:
1. Check and repair the pipeline
2. Check and replace the flushing solenoid valve
3. Check and repair the recycling system
永旺彩票8、 The pressure is sufficient, but the pressure display is not in place
1. Foreign matters in the pressure gauge hose are blocked
2. There is air in the hose
3. Pressure gauge failure
resolvent:
1. Check and dredge the pipeline
永旺彩票2. Remove air
3. Replace the pressure gauge
9、 Deterioration of water quality
1. Membrane pollution and scaling
永旺彩票2. Aging and failure of membrane junction seal
resolvent:
1. Carry out chemical cleaning according to technical requirements
2. Replace O-ring
永旺彩票3. Replace the membrane
永旺彩票10、 Production decline
永旺彩票1. For membrane pollution and scaling, chemical cleaning shall be carried out according to the technical requirements
2. The water temperature change shall be recalculated according to the actual water temperature to determine the water production.